LED module VIDEX VL-MLC-244 24W 4000K
LED module VIDEX VL-MLC-244 24W 4000K
-
EAN:4820246485982
-
On-mode power (Pon):24 W
-
Useful luminous flux (Φuse):2900 Lm
-
Light source or containing product:Light source
-
Correlated color temperature:4000K (neutral white)
-
Energy class of the light source:E
-
-
Rated voltage, frequency:AC 175-250 V, 50/60 Hz
-
Beam angle:120°
-
Place of installation :In the light fixture
-
Place of application:indoor
-
Rated current:218 mA
-
Displacement factor (cos φ1):-
-
Color rendering index (CRI):Ra > 80
-
Lifetime (L70B50):25000 h
-
On/Off cycles:20000
-
Housing colour:White
-
Input interface:Terminal block
-
Useful luminous flux of the light source reference:in a sphere (360°)
-
Electric shock protection class:II
-
Diffuser material:Polycarbonate (PC)
-
Ultraviolet radiation:no
-
Operating temperature range:-20° +40°C
-
Dimmable:no
-
Mercury content:Does not contain
-
Ingress protection:IP20
-
Housing material:Aluminum
-
Height:215 mm
-
Width:215 mm
-
Depth:23 mm
-
In the package:1 pc.
-
Outer box:20 pcs.
-
Unit nett weight:120g
-
Warranty:2 years
-
LED module VIDEX VL-MLC-244 24W 4000K is designed as a replacement light source for ceiling fixtures. In case the fixture breaks, it is enough to install the module into the fixture. Mounting is done using magnets or screws, and there is no need to spend time reinstalling a new fixture. ATTENTION! The built-in LED module is not intended to be installed outside the fixture or with an open or damaged diffuser. The package includes a user manual and individual packaging.
TECHNICAL SPECIFICATIONS:
- the light sources of the fixture are non-replaceable
- operates on a 175–250V AC mains supply, ensuring stable performance under voltage fluctuations
- power – 24W
- luminous flux – 2900Lm
- time to reach 100% of full luminous flux <1 sec
- beam angle – 120°
- color temperature – 4000K
- not compatible with dimmers
- number of ON/OFF cycles – 20 000
service life – 25 000 hours
- energy class – E, high energy efficiency
- ingress protection – IP20 (use in enclosed fixtures that protect against water droplets)
- protection class II (electric shock protection)
- the product does not contain harmful substances
INSTALLATION AND CONNECTION INSTRUCTIONS
During the entire process of replacing the light source, be sure to disconnect the power supply. Read the instructions before installation. Installation must be carried out by a qualified specialist. Please perform the installation and connection according to the wiring diagram provided in the instructions. Before first use, check the correctness of mechanical fastening and connections. The product can only be used on a power supply network that meets the energy requirements and quality standards established by law.
SAFETY PRECAUTIONS
1. Any maintenance work must be carried out with the electricity turned off and the product cooled to room temperature.
2. The product may only be powered by the rated voltage or voltage within the specified range.
3. Do not use the product with a damaged diffuser, damaged wiring, or damaged connection points.
4. Do not cover the product with thermal insulation materials.
5. Do not look directly at the LED beam.
6. Do not use the product in adverse conditions such as dust, water, moisture, vibration, explosive atmospheres, fumes or chemical vapors, etc.
7. The product is not repairable. Do not attempt to repair a broken product, as this will void the warranty.
8. A used or damaged product must be disposed of in accordance with applicable regulations.
Failure to follow these instructions may result, for example, in fire, burns, electric shock, bodily injury, and other material or immaterial damage. The manufacturer is not responsible for any damage caused by failure to follow the above instructions.
Warranty period is 2 years.